-25 Ambinent Temp EVI Air source heat pumpEVI Split Heat Pump Product Introduction:
This EVI heat pump is mainly designed for the cold weather area, it comprises indoor unit and outdoor units, which work together to provide hot water
and heating or cooling function, even under - 25°C low ambient temperature. The water system in the indoor unit, to ensure better anti-freezing and
decrease the heat dissipate. The compressor is available to be built in the outdoor unit or indoor unit. On the other hand, outdoor unit includes nylon
fan and evaporator with thermostatic heating element to prevent frosting.
EVI Split Heat Pump Features:
Indoor unit mainly includes condensor, 4-way valve and expansion valve.
1. Avoid the condensor to be burst in the cold weather, better anti-freezing protection
2. High efficient, lower heat dissipate
Outdoor unit comprises evaporator, fan and compressor.
1. Thermostatic heating element for evaporator anti-frosting protection
2. The water connections and the drain pipelines must be protected against frost on site
3. Compressor is outside, to reduce noise mostly inside the house
Auxiliary electronic heater or solar coiler is on your option.
Fashionable design, compact structure, saving space.
Quiet, lower noise when the unit is running.
Advanced control panel. Timer function, automatic defrosting function, optional electrical heating, error messages showed for warning.
It can be working on -25°C low ambient temperature.
Hot water output temperature up to 60°C, for domestic hot water or heating.
Auto-defrosting function included, cooling is optional.
EVI Split Heat Pump Main Components:
Compressor: Copeland new designed scroll compressor with gas injection increase enthalpy
Heat exchanger: Coaxial Coil tube-in-tube heat exchanger & Stainless steel plate heat exchanger
Evaporator: Hydrophilic high efficiency fin-tube evaporator, Golden color
Expansion valves: Main thermal expansion valves & Spray thermal expansion valves
Electromagnetic valve: Emerson electromagnetic valve
Fan: FULIHUA fan with nylon fiber blades, durable, lower noise, longer life
Controller: HOTSONG self-designed multi-functional digital control panel
EVI low temprature heat pump(heating/hot water ) |
|
Model |
MG-03KFGRS |
MG-045KFGRS |
MG-03KFGRS/380 |
MG-05KFGRS |
MG-10KFGRS |
MG-20KFGRS |
|
Heating capacity |
|
|
|
20ºC |
kW |
10 |
18.5 |
11 |
20 |
40 |
78 |
|
Heating input power |
|
|
|
kW |
2.45 |
4.48 |
2.7 |
4.85 |
9.8 |
19 |
|
Rated current |
|
|
|
A |
11.7 |
21.4 |
5.4 |
9.7 |
19.6 |
38.0 |
|
COP |
|
|
|
|
4.08 |
4.13 |
4.07 |
4.12 |
4.08 |
4.11 |
|
Hot water capacity |
|
|
|
L/H |
215 |
398 |
236 |
430 |
860 |
1677 |
|
Heating capacity |
|
|
|
7ºC |
kW |
8 |
14.8 |
8.8 |
16 |
32 |
62.4 |
|
Heating input power |
|
|
|
kW |
2.31 |
4.32 |
2.56 |
4.68 |
9.40 |
18.20 |
|
COP |
|
|
|
|
3.46 |
3.43 |
3.44 |
3.42 |
3.40 |
3.43 |
|
Hot water capacity |
|
|
|
L/H |
172 |
318 |
189 |
344 |
688 |
1341 |
|
Heating capacity |
|
|
|
-10ºC |
kW |
5.6 |
10.4 |
6.2 |
11.2 |
22.4 |
43.7 |
|
Heating input power |
|
|
|
kW |
2.15 |
4.05 |
2.40 |
4.45 |
8.80 |
17.80 |
|
COP |
|
|
|
|
2.60 |
2.56 |
2.57 |
2.52 |
2.55 |
2.45 |
|
Hot water capacity |
|
|
|
L/H |
120 |
223 |
132 |
241 |
482 |
939 |
|
Heating capacity |
|
|
|
-20ºC |
kW |
4.2 |
7.8 |
4.6 |
8.4 |
16.8 |
32.8 |
|
Heating input power |
|
|
|
kW |
2.05 |
3.82 |
2.30 |
4.21 |
8.10 |
16.20 |
|
COP |
|
|
|
|
2.05 |
2.03 |
2.01 |
2.00 |
2.07 |
2.02 |
|
Hot water capacity |
|
|
|
L/H |
90 |
167 |
99 |
181 |
361 |
704 |
|
Power supply |
220~240V/50Hz/1ph |
380V~415V/50Hz/3ph |
|
Rated/Max outlet water temp |
ºC |
55~60 |
|
Level of protection |
IPX4 |
|
Electric shock proof grade |
I |
|
Water flow |
m3/H |
2.1 |
4.0 |
2.4 |
4.3 |
8.6 |
16.8 |
|
Water pressure drop |
kPa |
≤38 |
≤40 |
≤38 |
≤43 |
≤50 |
≤65 |
|
Refrigerant |
R407C |
|
Compressor |
Copeland EVI compressor |
|
Compressor model * qty |
ZW34KSE*1 |
ZW52KSE*1 |
ZW34KSE*1 |
ZW61KSE*1 |
ZW61KSE*2 |
ZW108KSE*2 |
|
Condenser |
High efficient tube-in-shell heat exchanger |
|
Evaporator |
Blue hydrophilic aliuminium foil,wavy fin and copper tube heat exchanger |
|
Fan Motor |
90W*1 |
90W*2 |
90W*1 |
90W*2 |
550W*2 |
800W*2 |
|
Economy unit |
Stainless steel Plate heat exchanger |
|
4-way valve |
SHF-11-45D1*1 |
SHF-20A-46*1 |
SHF-11-45D1*1 |
SHF-20A-46*1 |
SHF-20A-46*2 |
SHF-35A-79*2 |
|
Throttle unit |
Thermal expansion valve |
|
A/C contactor and Thermal relay |
LG Brand |
|
Controller |
Microcomputer central processor (LCD wire controller) |
|
Protection function |
temperature protection, time protection, water flow protection, antifreeze protection, current protection |
|
Ambient temperature |
(-25ºC -- 46ºC) |
|
High pressure switch |
3.0/3.4MPa |
|
Low pressure switch |
0.05/0.15MPa |
|
Water pipe size |
|
DN25 |
DN25 |
DN25 |
DN25 |
DN32 |
DN50 |
|
Noise |
dB(A) |
≤50 |
≤55 |
≤50 |
≤55 |
≤65 |
≤70 |
|
Dimension |
L*W*H |
830*490*1160 |
1095*420*1420 |
830*490*1160 |
1095*420*1420 |
1500*800*1550 |
2170*1065*1890 |
|
Weight |
kg |
112 |
164 |
112 |
164 |
320 |
580 |
|
Guarantee for18 months. During the guarantee period , our company will be responsible for problems caused by quality of production or raw material except the damageable spare parts of heat pump caused by incorrect man-made operation. |
|
In stock for next day delivery. If no stock, After receive you deposit within 20 days |
|
Packaging details: |
|
Plywood case |
|
|
Functions: |
|
1.inquire temperatures of water and refrigerant and ambient air. |
|
|
|
|
|
|
|
2.defrost autumatically in cold weather |
|